Last edited by Goltitaxe
Friday, August 7, 2020 | History

2 edition of multichannel magnetic analyzer for pulsed plasma sources found in the catalog.

multichannel magnetic analyzer for pulsed plasma sources

J. E. Osher

multichannel magnetic analyzer for pulsed plasma sources

by J. E. Osher

  • 100 Want to read
  • 30 Currently reading

Published by Dept. of Energy, [Office of the Assistant Secretary for Defense Programs], Lawrence Livermore Laboratory, for sale by the National Technical Information Service in [Livermore, Calif.], Springfield, Va .
Written in English

    Subjects:
  • Magnetic analyzers (Nuclear physics)

  • Edition Notes

    StatementJ. E. Osher and W. J. Stroh, Lawrence Livermore Laboratory ; prepared for U.S. Department of Energy
    SeriesUCID ; 17806
    ContributionsStroh, W. J., joint author, United States. Dept. of Energy, Lawrence Livermore Laboratory
    The Physical Object
    Pagination13 leaves :
    Number of Pages13
    ID Numbers
    Open LibraryOL14884464M

    Plasma dynamics in pulsed strong magnetic fieldsa plasma source that is mounted outside the gap, a few cm from the anode. The flashboard plasma is mainly composed of protons and C III–V ions Secondary plasma, produced due to the impinging primary plasma on the electrodes, is. mJ/pulse in nanoseconds at nanometers, which can be focused to 25 micrometers, giving rise to power densities of about 6 ×10 13 W/cm 2. Equally impressive advances in plasma technology, including photon channeling with inert gases, show promise for additional order-of-magnitude increases in plasma photon , it is.

    Plasma dynamics in pulsed strong magnetic fields. Power Tools for Health: How pulsed magnetic fields (PEMFs) help you by Msc William Pawluk MD and Caitlin Layne | out of 5 stars

    Get this from a library! IEEE standard multichannel analyzer (MCA) histogram data interchange format for nuclear spectroscopy. [IEEE Nuclear and Plasma Sciences Society. Nuclear Instruments and Detectors Committee.; Institute of Electrical and Electronics Engineers.; IEEE Standards Board.;] -- A standard format for data interchange used to transfer multichannel pulse height data on magnetic. Buy Pulsed Electromagnetic Field Therapy Mat (PEMF): Magnetic Therapy (PEMFT), also known as PEMF, pulse magnetotherapy, and pulsed magnetic therapy. PEMFT is a therapy technique used in many ways, for example in depression & orthopedics treating fusions, fractures. When dealing with bone healing, PEMF sends magnetic pulses through the.


Share this book
You might also like
Sprayed asbestos-containing materials in buildings

Sprayed asbestos-containing materials in buildings

Stone cold

Stone cold

They were first

They were first

Microbial Contamination in Parenteral Manufacturing (Drugs and the Pharmaceutical Sciences)

Microbial Contamination in Parenteral Manufacturing (Drugs and the Pharmaceutical Sciences)

Bookmarks

Bookmarks

Corderii colloquiorum centuria selecta

Corderii colloquiorum centuria selecta

Olson family history, 1650-2002

Olson family history, 1650-2002

Letters to Paul Amann, 1915-1952.

Letters to Paul Amann, 1915-1952.

Bottom trawl codend mesh selectivity for Bagrus docmac (Forskahl) from Lake Victoria

Bottom trawl codend mesh selectivity for Bagrus docmac (Forskahl) from Lake Victoria

Cooking by electricity

Cooking by electricity

Filipinos in Alaska, 1788-1958

Filipinos in Alaska, 1788-1958

The Jātaka, or, Stories of the Buddhas former births

The Jātaka, or, Stories of the Buddhas former births

Thomas and Harriet Gibbons Georgian Silver Collection and other silver at Lauren Rogers Library and Museum of Art, Laurel, Mississippi.

Thomas and Harriet Gibbons Georgian Silver Collection and other silver at Lauren Rogers Library and Museum of Art, Laurel, Mississippi.

Multichannel magnetic analyzer for pulsed plasma sources by J. E. Osher Download PDF EPUB FB2

Get this from a library. A multichannel magnetic analyzer for pulsed plasma sources. [J E Osher; W J Stroh; United States. Department of Energy.; Lawrence Livermore Laboratory.]. A multichannel mass and energy analyzer using crossed electric and magnetic fields for ion separation has been constructed to analyze plasmas produced in conjunction with a magnetic mirror machine.

Ions are piped between the strong magnetic field of the mirror machine and the weaker magnetic field of the analyzer by auxiliary magnetic coils, and they enter the analyzer traveling in a Cited by: MICHAEL F. L'ANNUNZIATA, in Handbook of Radioactivity Analysis (Second Edition), 1.

Multichannel Analysis. The multichannel analyzer (MCA) in liquid scintillation analysis is described in detail in Chapter 5 on liquid scintillation analysis (LSA). The application of the MCA in flow scintillation analysis as in LSA will sort all signals according to pulse height into individual channels.

A low-power, plasma source-based, portable molecular emission detector is described in this paper. The detector employs a pulsed-plasma source operated at atmospheric pressure for molecular fragmentation and excitation. The plasma was generated with a home-built high-voltage pulsed power supply.

The average operational power of the detector was less than by: A novel mass spectrometer system for elemental analysis is described. The instrument combines an inductively coupled plasma (ICP) ion source with a Mattauch-Herzog mass spectrometer and multichannel ion detector.

Multichannel magnetic analyzer for pulsed plasma sources book detection is simultaneous and an elemental mass spectrum (20– μ) can be acquired in plasma sources.

The Cited by: Over the past few decades many diagnostics have been developed to study the non-equilibrium nature of plasma. These developments have given experimentalists the possibility to measure in situ molecular and atomic densities, electron and ion densities, temperatures and velocities of species in the plasma, to just name a few.

Many of the diagnostic techniques are based on the ‘photon-in. It was also proposed that the strong pulsed magnetic field in the arc source interacts with the plasma flux.

Continuous plasma flux is formed at starting discharge voltages below V. Pulsing character of the plasma flux is seen at higher voltages. Maximum energy of carbon ions during the pulse is achieved at a distance of mm from the. Investigation of the self-induced magnetic field characteristics in a pulsed plasma thruster with flared electrodes 31 December | Plasma Science and Technology, Vol.

22, No. 3 A review of the characterization and optimization of ablative pulsed plasma thrusters. A comparative study of ablation plasma plumes originated from single crystal graphite (SCG) and amorphous carbon (a-C) targets during the preparation of diamond-like carbon (DLC) films by KrF excimer pulsed laser deposition (PLD) has been carried out by means of a monochromator equipped with an intensified optical multichannel analyzer.

In high vacuum, the emission lines of carbon. In a chemistry laboratory, a retort is a device used for distillation or dry distillation of substances. It consists of a spherical vessel with a long downward-pointing neck. The liquid to be distilled is placed in the vessel and heated.

The neck acts as a condenser, allowing the vapors to condense and flow along the neck to a collection vessel placed underneath. The pulsed ion source developed and built in CEA/Saclay operates with a frequency of GHz based on ECR plasma production with two coils with mT magnetic field necessary for the electron.

A magnetic pulse compression (MPC) pulsed power modulator able to deliver pulse repetition rates up to Hz, with J per pulse energy output at 25 kV, was used as the pulsed power source. The electric and magnetic fields that exist in electric propulsion plasmas obey Maxwell’s equations formulated in a vacuum that contains charges and currents.

Maxwell’s equations for these conditions are E= o () E= B t () B=0 () B= μo J+ o E t, () where is the charge density in the plasma, J is the current density in the. The plasma magnet’s thrust is the force of the solar wind pushing against the magnetosphere as it is deflected around it.

It functions like a square-rigged sail running before the wind. Figure 2. Plasma magnetic sail based on rotating magnetic field generated plasma currents.

TDHP40BAS - Series: Powerful, Versatile, and Highly Adjustable: Easy to use and designed with our most recent fast nano-sec rise time truncated square wave pulse technology (creditable to NASA research).The use of pulsed magnetic therapy is recognized in Canada and Europe as a beneficial aid to many ailments, chronic pain and other health issues.

The Teclu burner is a laboratory gas burner, a variant of the Bunsen burner, named after the Romanian chemist Nicolae can produce a hotter flame than a Bunsen burner. The lower part of its tube is conical, with a round screw nut below its base. The gap, set by the distance between the nut and the end of the tube, regulates the influx of the air in a way similar to the open slots of.

This spectrograph is coupled to a channel optical multichannel analyzer. Spectra taken during the initial ns period of the e-beam pulse showed a low effective charge plasma with primarily molecular components (C2, CH) as well as atomic hydrogen and singly ionized carbon (CII). @article{osti_, title = {Multichannel neutral-particle analyzer system}, author = {Nexsen, Jr, W E and Turner, W C and Cummins, W F}, abstractNote = {A multichannel neutral-analyzer system developed for the analysis of charge-exchange flux from magnetically confined plasma is described.

The system uses tandem magnetic--electrostatic deflection of ions produced from neutrals stripped in. The ion source anode is at a positive potential, either dc or pulsed, with respect to the source cathode. The ion source voltage is normally between 2 and 7 kilovolts. A magnetic field, oriented parallel to the source axis, is produced by a permanent magnet.

Heating or cooling the gas reservoir element regulates the gas pressure in the source. Presently, the Plasma, Power Electronics, and Pulsed Power Research Programs are Funded at nearly $4, per year.

The work conducted at the Center For Pulsed Power and Power Electronics focuses on: Electrical space propulsion devices. This is the resource that engineers turn to in the study of radiation detection. The fourth edition takes into account the technical developments that continue to enhance the instruments and techniques available for the detection and spectroscopy of ionizing radiation.Abstract.

Recently there has been a growing interest in sharpening electric and magnetic pulses in order to improve a wide variety of pulsed sources like compact particle accelerators 1, X-ray sources essential tool for pulse sharpening is the saturable magnetic switch.motion around magnetic field lines • We say plasma is tied to field lines, which have magnetic tension and pressure • In plasmas with high electrical conductivity, magnetic field • Cost of electricity competitive with today’s sources.

Tokamaks are the most successful magnetic confinement concept.